Standards
|
I Meet or Exceed NACHI
Standards of Practice
1. Definitions and Scope
1.1. A Home inspection is a non-invasive
visual examination of a residential
dwelling, performed for a fee, which is
designed to identify observed material
defects within specific components of said
dwelling. Components may include any
combination of mechanical, structural,
electrical, plumbing, or other essential
systems or portions of the home, as
identified and agreed to by the Client and
Inspector, prior to or during the inspection
process.
I. A home inspection is intended to
assist in evaluation of the overall
condition of the dwelling. The
inspection is based on observation of
the visible and apparent condition of
the structure and its components on the
date of the inspection and not the
determination of future conditions.
II. A home inspection will not reveal
every problem that exists or ever could
exist, but only those material defects
observed on the day of the inspection.
1.2. A Material defect is a problem with a
residential real property or any portion of
it that would have a significant adverse
impact on the value of the property or that
involves an unreasonable risk to people on
the property. The fact that a structural
element, system or subsystem is near, at or
beyond the end of the normal useful life of
such a structural element, system or
subsystem is not by itself a material
defect.
1.3. An Inspection report shall describe and
identify in written format the inspected
systems, structures, and components of the
dwelling and shall identify material defects
observed. Inspection reports may contain
recommendations regarding conditions
reported or recommendations for correction,
monitoring or further evaluation by
professionals.
2. Standards of Practice
2.1. Roof
I. The inspector shall inspect from
ground level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights,
chimney and other roof penetrations.
E. The general structure of the roof
from the readily accessible panels,
doors or stairs.
II. The inspector is not required to:
A. Walk on any roof surface.
B. Predict the service life
expectancy.
C. Inspect underground downspout
diverter drainage pipes.
D. Remove snow, ice, debris or other
conditions that prohibit the
observation of the roof surfaces.
E. Inspect antennae, lightning
arresters, or similar attachments.
2.2. Exterior
I. The inspector shall inspect:
A. The flashing and trim.
B. All exterior doors, decks,
stoops, steps, stairs, porches,
railings, eaves, soffits, fascias,
grading, and walkways.
C. And report as in need of repair
any spacings between intermediate
balusters, spindles, or rails for
steps, stairways, balconies, and
railings that permit the passage of
an object greater than four inches
in diameter.
D. The vegetation, surface drainage
and retaining walls when these are
likely to adversely affect the
building.
E. And describe the exterior wall
covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm
windows, shutters, awnings, fences,
outbuildings, or exterior accent
lighting.
B. Inspect items, including window
and door flashings, which are not
visible or readily accessible from
the ground.
C. Inspect geological, geotechnical,
or hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and
docks.
F. Inspect erosion control and earth
stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or
cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the
thermal window seals or damaged
glass.
2.3. Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural
components.
E. Any present conditions or
indications of active water
penetration by probing a
representative sampling of
structural components where
deterioration is believed to be
present or where clear indications
of deterioration are present.
F. And report any general
indications of foundation movement
that are observed, such as but not
limited to sheetrock cracks, brick
cracks, out-of-square door frames or
floor slopes.
II. The inspector is not required to:
A. Enter any crawlspaces that are
not readily accessible or where
entry could cause damage or pose a
hazard to the inspector in his or
her opinion.
B. Move stored items or debris.
C. Operate sump pumps with
inaccessible floats.
D. Identify size, spacing, span,
location or adequacy of foundation
bolting, bracing, joists or support
systems.
E. Provide any engineering or
architectural service.
F. Report on the adequacy of any
structural system or component.
2.4. Heating
I. The inspector shall inspect:
A. The heating system and describe
the energy source and heating method
using normal operating controls.
B. And report as in need of repair
electric furnaces which do not
operate.
C. And report if inspector deemed
the furnace inaccessible.
II. The inspector is not required to:
A. Inspect or evaluate interiors of
flues or chimneys, fire chambers,
the heat exchanger, the humidifier
or dehumidifier, the electronic air
filter, solar heating systems or
fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity,
temperature, flow, balance,
distribution, size, capacity, BTU,
or supply adequacy of the heating
system.
D. Light pilot flames.
E. Activate heating, heat pump
systems, or other heating systems
when ambient temperatures or other
circumstances are not conducive to
safe operation or may damage the
equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment
using normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity,
temperature, flow, balance,
distribution, size, capacity, BTU,
or supply adequacy of the cooling
system.
B. Inspect window units,
through-wall units, or electronic
air filters.
C. Operate equipment or systems if
exterior temperature is below 60
degrees Fahrenheit or when other
circumstances are not conducive to
safe operation or may damage the
equipment.
D. Inspect or determine thermostat
calibration, heat anticipation or
automatic setbacks or clocks.
E. Examine electrical current,
coolant fluids or gasses, or coolant
leakage.
2.6. Plumbing
I. The inspector shall:
A. Inspect the main water shut
off valve.
B. Inspect the water heating
equipment, including combustion
air, venting, connections,
energy sources, seismic bracing,
and verify the presence or
absence of temperature-pressure
relief valves and/or Watts 210
valves.
C. Flush toilets.
D. Run water in sinks, tubs, and
showers.
E. Inspect the interior water
supply including all fixtures
and faucets.
F. Inspect the drain, waste and
vent systems, including all
fixtures.
G. Describe any visible fuel
storage systems.
H. Inspect the drainage sump
pumps testing sumps with
accessible floats.
I. Inspect and describe the
water supply, drain, waste and
main fuel shut-off valves, as
well as the location of the
water main and main fuel
shut-off valves.
J. Inspect and determine if the
water supply is public or
private.
K. Inspect and report as in need
of repair deficiencies in the
water supply by viewing the
functional flow in two fixtures
operated simultaneously.
L. Inspect and report as in need
of repair deficiencies in
installation and identification
of hot and cold faucets.
M. Inspect and report as in need
of repair mechanical drain-stops
that are missing or do not
operate if installed in sinks,
lavatories and tubs.
N. Inspect and report as in need
of repair commodes that have
cracks in the ceramic material,
are improperly mounted on the
floor, leak, or have tank
components which do not operate.
II. The inspector is not required to:
A. Light pilot flames.
B. Determine the size,
temperature, age, life
expectancy or adequacy of the
water heater.
C. Inspect interiors of flues or
chimneys, water softening or
filtering systems, well pumps or
tanks, safety or shut-of valves,
floor drains or sprinkler
systems.
D. Determine the exact flow
rate, volume, pressure,
temperature, or adequacy of the
water supply.
E. Determine the water quality
or potability or the reliability
of the water supply or source.
F. Open closed plumbing access
panels.
G. Inspect clothes washing
machine connections.
H. Operate any main, branch or
fixture valve except fixture
faucets and hose faucets
attached to the building.
I. Test shower pans, tub and
shower surrounds or enclosures
for leakage.
J. Evaluate the compliance with
local or state conservation or
energy standards, or the proper
design or sizing of any water,
waste or venting components,
fixtures or piping.
K. Determine the effectiveness
of anti-siphon, back-flow
prevention or drain-stop
devices.
L. Determine whether there are
sufficient clean-outs for
effective cleaning of drains.
M. Evaluate gas, liquid propane
or oil storage tanks.
N. Excavate or otherwise uncover
the private sewage system or its
components to determine size,
adequacy or efficiency.
O. Inspect water treatment
systems or water filters.
P. Inspect pressure pumps or
bladder tanks.
Q. Evaluate time to obtain
hot water at fixtures, or
perform testing of any kind
to water heater elements.
R. Evaluate or determine the
adequacy of combustion air.
S. Test, operate, open or
close Watts 210 valves
and/or TPR valves.
T. Examine ancillary systems
or components, such as, but
not limited to, those
relating to solar water
heating, hot water
circulation.
2.7. Electrical
I. The inspector shall inspect:
A. The service line.
B. The meter box.
C. The main disconnect.
D. And determine the service
amperage.
E. Panels, breakers and fuses.
F. The grounding.
G. The bonding.
H. A representative sampling of
switches, receptacles, light
fixtures, and test all GFCI
receptacles and GFCI circuit
breakers observed and deemed to
be GFCI's during the inspection.
I. And report the presence of
solid conductor aluminum branch
circuit wiring if readily
visible.
J. And report on any
GFCI-tested receptacles in which
power is not present, polarity
is incorrect, the receptacle is
not grounded, is not secured to
the wall, the cover is not in
place, the ground fault circuit
interrupter devices are not
properly installed or do not
operate properly, or evidence of
arcing or excessive heat is
present.
K. The service entrance
conductors and the condition of
their sheathing.
L. The ground fault circuit
interrupters with a GFCI tester.
M. And describe the amperage
rating of the service.
N. And report the absence of
smoke detectors.
O. Service entrance cables and
report as in need of repair
deficiencies in the integrity of
the insulation, drip loop, or
separation of conductors at
weatherheads and clearances.
II. The inspector is not required to:
A. Insert any tool, probe or device
into the main or sub-panels.
B. Operate electrical systems that
are shut down.
C. Remove panel covers or dead front
covers if not readily accessible.
D. Operate over current protection
devices.
E. Operate non-accessible smoke
detectors.
F. Measure or determine the amperage
or voltage of the main service if
not visibly labeled.
G. Inspect the alarm system and
components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems
or branch circuits which are not
energized.
J. Operate overload devices.
K. Inspect low voltage systems,
electrical de-icing tapes, swimming
pool wiring or any time-controlled
devices.
L. Verify the continuity of the
connected service ground.
M. Inspect private or emergency
electrical supply sources, including
but not limited to generators,
windmills, photovoltaic solar
collectors, or battery or electrical
storage facility.
N. Inspect spark or lightning
arrestors.
O. Conduct drop voltage
calculations.
P. Determine the accuracy of breaker
labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close
the damper door if readily
accessible and operable.
B. Hearth extensions and other
permanently installed components.
C. And report as in need of repair
deficiencies in the lintel, hearth
and material surrounding the
fireplace, including clearance from
combustible materials
II. The inspector is not required to:
A. Inspect the vent system.
B. Inspect the interior of the
chimney or flue, fire doors or
screens, seals or mantels.
C. Determine the need for a chimney
sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of
such installation.
G. Inspect automatic fuel feed
devices.
H. Inspect combustion make up
devices.
I. Inspect heat distribution assists
whether gravity controlled or fan
assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves,
or firebox contents.
M. Determine adequacy of draft,
perform a smoke test or dismantle or
remove any component.
2.9. Attic, Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished
spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence
or lack of insulation.
II. The inspector is not required to:
A. Enter the attic or unfinished
spaces that are not readily
accessible or where entry could
cause damage or pose a safety hazard
to the inspector in his or her
opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the
surface finish or weather seal on or
around access panels and covers.
E. Identify the composition or the
exact R-value of insulation
material.
F. Activate thermostatically
operated fans.
G. Determine the types of materials
used in insulation/wrapping of
pipes, ducts, jackets, boilers, and
wiring.
2.10. Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative
number of doors and windows.
B. Inspect the walls, ceilings,
steps, stairways, and railings.
C. Inspect garage doors and garage
door openers by operating first
by remote (if available) and then by
the installed automatic door
control.
D. And report as in need of repair
any installed electronic sensors
that are not operable or not
installed at proper heights above
the garage door.
E. And report as in need of repair
any door locks or side ropes that
have not been removed or disabled
when garage door opener is in use.
F. And report as in need of repair
any windows that are obviously
fogged or display other evidence of
broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window
treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in
locations subject to human impact.
D. Inspect security components.
E. Evaluate the fastening of
countertops, cabinets, sink tops and
fixtures, or firewall compromises.
F. Move furniture, stored items, or
any coverings like carpets or rugs
in order to inspect the concealed
floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household
appliances.
I. Inspect or operate equipment
housed in the garage except as
otherwise noted.
J. Verify or certify safe operation
of any auto reverse or related
safety function of a garage door.
K. Operate or evaluate security bar
release and opening mechanisms,
whether interior or exterior,
including compliance with local,
state, or federal standards.
L. Operate any system, appliance or
component that requires the use of
special keys, codes, combinations,
or devices.
M. Operate or evaluate self-cleaning
oven cycles or signal lights.
N. Determine leakage from microwave
ovens.
O. Operate or examine any sauna,
steam-jenny, kiln, toaster,
ice-maker, coffee-maker, can-opener,
bread-warmer, blender, instant hot
water dispenser, or other small,
ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently
installed.
T. Examine or operate any
above-ground, movable, freestanding,
or otherwise non-permanently
installed pool/spa or self-contained
equipment.
U. Come into contact with any pool
or spa water in order to determine
the system structure or components.
V. Determine the adequacy of spa jet
water force or bubble effect.
W. Determine the structural
integrity or leakage of a pool or
spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically
exhaustive.
II. An inspection will not identify
concealed or latent defects.
III. An inspection will not deal with
aesthetic concerns or what could be
deemed matters of taste, cosmetic, etc.
IV. An inspection will not determine the
suitability of the property for any use.
V. An inspection does not determine the
market value of the property or its
marketability.
VI. An inspection does not determine the
advisability or inadvisability of the
purchase of the inspected property.
VII. An inspection does not determine
the life expectancy of the property or
any components or systems therein.
VIII. An inspection does not include
items not permanently installed.
IX. These Standards of Practice apply
only to homes with four or fewer
dwelling units.
3.2. Exclusions:
I. The inspectors are not required to
determine:
A. Property boundary lines or
encroachments.
B. The condition of any component or
system that is not readily
accessible.
C. The service life expectancy of
any component or system.
D. The size, capacity, BTU,
performance, or efficiency of any
component or system.
E. The cause or reason of any
condition.
F. The cause for the need of repair
or replacement of any system or
component.
G. Future conditions.
H. The compliance with codes or
regulations.
I. The presence of evidence of
rodents, animals or insects.
J. The presence of mold, mildew or
fungus.
K. The presence of air-borne
hazards.
L. The presence of birds.
M. The presence of other flora or
fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental
hazards.
Q. The existence of electro-magnetic
fields.
R. The presence of hazardous
materials including, but not limited
to, the presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or
conformance with manufacturer
installation or any information
included in the consumer protection
bulletin.
U. Operating costs of systems.
V. Replacement or repair cost
estimates.
W. The acoustical properties of any
systems.
X. Estimates of how much it will
cost to run any given system.
II. The inspectors are not required to
operate:
A. Any system that is shut down.
B. Any system that does not function
properly.
C. Or evaluate low voltage
electrical systems such as, but not
limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on
with the use of normal operating
controls.
E. Any shut off valve.
F. Any electrical disconnect or over
current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or
similar equipment.
III. The inspectors are not required to:
A. Move any personal items or other
obstructions, such as, but not
limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any
system or component.
C. Enter or access any area which
may, in the opinion of the
inspector, to be unsafe or risk
personal safety.
D. Enter crawlspaces or other areas
that are unsafe or not readily
accessible.
E. Inspect underground items such
as, but not limited to, underground
storage tanks or other indications
of their presence, whether abandoned
or actively used.
F. Do anything which, in the
inspector's opinion, is likely to be
unsafe or dangerous to the inspector
or others or damage property, such
as, but not limited to, walking on
roof surfaces, climbing ladders,
entering attic spaces or negotiating
with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas
in multi-unit housing.
I. Inspect intercoms, speaker
systems, radio-controlled, security
devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering
services.
L. Offer or perform any trade or
professional service other than home
inspection.
M. Research the history of the
property, report on its potential
for alteration, modification,
extendibility, or its suitability
for a specific or proposed use for
occupancy.
N. Determine the age of construction
or installation of any system
structure, or component of a
building, or differentiate between
original construction or subsequent
additions, improvements, renovations
or replacements thereto.
O. Determine the insurability of a
property.
4. Glossary of Terms
4.1. Accessible: Can be approached or
entered by the inspector safely, without
difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or
enable systems, equipment, or devices to
become active by normal operating controls.
Examples include turning on the gas or water
supply valves to the fixtures and appliances
and activating electrical breakers or fuses.
4.3. Adversely Affect: Constitute, or
potentially constitute, a negative or
destructive impact.
4.4. Alarm System: Warning devices,
installed or free-standing, including but
not limited to: Carbon monoxide detectors,
flue gas and other spillage detectors,
security equipment, ejector pumps and smoke
alarms.
4.5. Appliance: A household device operated
by use of electricity or gas. Not included
in this definition are components covered
under central heating, central cooling or
plumbing.
4.6. Architectural Service: Any practice
involving the art and science of building
design for construction of any structure or
grouping of structures and the use of space
within and surrounding the structures or the
design, design development, preparation of
construction contract documents, and
administration of the construction contract.
4.7. Component: A permanently installed or
attached fixture, element or part of a
system.
4.8. Condition: The visible and conspicuous
state of being of an object.
4.9. Crawlspace: The area within the
confines of the foundation and between the
ground and the underside of the lowest floor
structural component.
4.10. Decorative: Ornamental; not required
for the operation of essential systems and
components of a home.
4.11. Describe: Report in writing a system
or component by its type, or other observed
characteristics, to distinguish it from
other components used for the same purpose.
4.12. Determine: To arrive at an opinion or
conclusion pursuant to examination.
4.13. Dismantle: To open, take apart or
remove any component, device or piece that
would not typically be opened, taken apart
or removed by an ordinary occupant.
4.14. Engineering Service: Any professional
service or creative work requiring
engineering education, training, and
experience and the application of special
knowledge of the mathematical, physical and
engineering sciences to such professional
service or creative work as consultation,
investigation, evaluation, planning, design
and supervision of construction for the
purpose of assuring compliance with the
specifications and design, in conjunction
with structures, buildings, machines,
equipment, works or processes.
4.15. Enter: To go into an area to observe
all visible components.
4.16. Evaluate: To assess the systems,
structures or components of a dwelling.
4.17. Examine: To visually look. See
Inspect.
4.18. Foundation: The base upon which the
structure or wall rests; usually masonry,
concrete, or stone, and generally partially
underground.
4.19. Function: The action for which an
item, component, or system is specially
fitted or used or for which an item,
component or system exists; to be in action
or perform a task.
4.20. Functional: Performing, or able to
perform, a function.
4.21. Home Inspection: The process by which
an inspector visually examines the readily
accessible systems and components of a home
and operates those systems and components
utilizing these Standards of Practice as a
guideline.
4.22. Household Appliances: Kitchen and
laundry appliances, room air conditioners,
and similar appliances.
4.23. Inspect: To visually look at readily
accessible systems and components safely,
using normal operating controls and
accessing readily accessible panels and
areas.
4.24. Inspected Property: The readily
accessible areas of the buildings, site,
items, components, and systems included in
the inspection.
4.25. Inspector: One who performs a real
estate inspection.
4.26. Installed: Attached or connected such
that the installed item requires tool for
removal.
4.27. Material Defect: Refer to section 1.2.
4.28. Normal Operating Controls: Devices
such as thermostats that would be operated
by ordinary occupants which require no
specialized skill or knowledge.
4.29. Observe: To see through visually
directed attention.
4.30. Operate: To cause systems to function
or turn on with normal operating controls.
4.31. Readily Accessible: An item or
component is readily accessible if, in the
judgment of the inspector, it is capable of
being safely observed without movement of
obstacles, detachment or disengagement of
connecting or securing devices, or other
unsafe or difficult procedures to gain
access.
4.32. Recreational Facilities: Spas, saunas,
steam baths, swimming pools, tennis courts,
playground equipment, and other exercise,
entertainment or athletic facilities.
4.33. Report: A written communication
(possibly including digital images) of any
material defects seen during the inspection.
4.34. Representative Number: A sufficient
number to serve as a typical or
characteristic example of the item(s)
inspected.
4.35. Safety Glazing: Tempered glass,
laminated glass, or rigid plastic.
4.36. Shut Down: Turned off, unplugged,
inactive, not in service, not operational,
etc.
4.37. Structural Component: A component
which supports non-variable forces or
weights (dead loads) and variable forces or
weights (live loads).
4.38. System: An assembly of various
components to function as a whole.
4.39. Technically Exhaustive: A
comprehensive and detailed examination
beyond the scope of a real estate home
inspection which would involve or include,
but would not be limited to: dismantling,
specialized knowledge or training, special
equipment, measurements, calculations,
testing, research, analysis or other means.
4.40. Unsafe: A condition in a readily
accessible, installed system or component
which is judged to be a significant risk of
personal injury during normal, day-to-day
use. The risk may be due to damage,
deterioration, improper installation or a
change in accepted residential construction
standards.
4.41. Verify: To confirm or substantiate.
The aforementioned terms are found within
the SOP.
Visit NACHI's full Glossary.